Fantini Cosmi ASPIRLIGHT HV handleiding
Handleiding
Je bekijkt pagina 17 van 24

17
ENGLISH
ASPIRLIGHT HV
5 EXTERNAL COIL INSTALLATION
5.1.1 ELECTRIC COILS
The unit can feature an electric coil that can be installed as described below.
The coil has an internal thermostat that can also be connected to an external thermostat. For details of the
electrical connections, follow the instructions provided in the coil manual
The CH193VMC remote panel directly controls the electric coil through the Chiller contact, on the board;
Deactivate or raise the setting in summer to prevent the coil from starting up in summer mode;
Coil with pre-heat function
The Coil defrosts the unit and provides an antifreeze protection function.
Installation:
install the heater on the “renewal air” duct;
connect the heater to the electrical mains;
set the temperature on the internal thermostat to 2°C;
The coil, in any case, needs to be installed with the cover upwards to prevent the safety devices from malfunctioning.
Coil with post-heat function
In winter, the purpose of the coil is to heat the air supplied into the home, to the requested comfort temperature.
Installation:
install the heater on the “supply” duct;
connect the heater to the electrical mains;
set the temperature on the internal thermostat to the required temperature (e.g. 18 °C);
The coil, in any case, needs to be installed with the cover upwards to prevent the safety devices from
malfunctioning.