B
Short Press or move your finger from left to right to increase the speed from
1 to 2, 3, Intensive.
The intensive speed is timed for 6 minutes. At the end of this time the
system automatically returns to the previously set speed.
Repeat the operation in reverse to decrease the speed (from right to
left).
The display shows the
selected speed.
If the Intensive speed is
selected the display
shows an animation.
Long press on
the leftmost lines
when all loads
are off (motor
and lights)
Keypad Lock function
Activates/deactivates the keypad lock for hood cleaning.
All LEDs flashing
Long press on
the rightmost
lines when all
loads are off
(motor and
lights)
Induction/Gas Cooktop Selection
Select the type of cooktop in use, either Induction or Gas.
The Induction Cooktop is set by default.
1 Flashing LED A: con-
firms the Induction
Cooktop selection.
2 Flashing LED A: con-
firms the Gas Cooktop
selection.
C
Short Switches the lights on/off at maximum intensity.
If there is an induction cooktop paired with the hood and the hood is
off, as soon as the induction cooktop is turned on, the hood lights
automatically turn on at the maximum intensity.
Fixed
Long press with
all loads off (mo-
tor and lights)
K-Link pairing
Before starting the procedure follow the specific instructions of the
manuals of the devices to be paired.
Starts the pairing procedure between the hood and compatible K-Link
devices (induction cooktop or remote control). Up to 3 induction cook-
tops can be paired and only one remote control. See the manual of
the devices for details of the operations that need to be performed on
these.
The pairing procedure takes 2 minutes. If no devices are recognised
within this time check that you have previously activated the proced-
ure for the devices to be paired. The maximum number of linkable
devices may have been reached.
The display shows an
animation:
Pairing in progress.
Upon successful com-
pletion of the procedure
all the LEDs will light up
for 2 seconds.
D
Short Switches the lights on/off at medium intensity. Fixed
Long press with
all loads off (mo-
tor and lights)
Performs a saturated Filters alarm reset.
The display shows F 3
times, indicating that the
filter reset has been
completed.
Signals the saturated Metal Grease Filters alarm and the need to
wash them. The alarm is activated after 100 hours of effective hood
operation.
With the motor off, the
display shows F + 1
multiple times altern-
ately.
Signals the saturated Activated Carbon Odour Filter alarm. The
alarm is activated after 200 hours of effective hood operation.
With the motor off, the
display shows F + 2
multiple times altern-
ately.
E Short
Delay Function
Activates/Deactivates the Delay function (automatic shutdown of the
Motor and of the lighting delayed by 30').
Cannot be activated with Intensive or 24h function.
Deactivate the function by pressing the same key or press the A key
for about 1 second to shut down the motor.
LED A remains lit (fixed)
and LED E lights up.
The display shows an
animation.
Long press with
light or motor on
24h Function
Activates/Deactivates the motor in the 24h Air Exchange mode, a
speed that allows suction of 10 minutes every hour, for a 24-hour
cycle.
Cannot be activated if the Intensive or Delay modes are active.
LED A remains lit (fixed)
and LED E flashes. The
display shows an anim-
ation.
Long press with
all loads off (mo-
tor and lights)
K-Link unpairing
Starts the procedure for the cancellation of all compatible K-Link
devices previously paired with the K-Link pairing function.
Upon successful com-
pletion of the procedure
all the LEDs flash 5
times.