Network Button Panels • Hardware Features and Installation — Wall-mountable Models 13
Decorator-style and US Gang Model Site Preparation
The NBP button panels t standard US junction boxes or mud rings.
Model Gang Size
NBP 105 D, NBP 106 D, NBP 108 D, NBP 110 D,
NBP VC1 D, NBP VC2 D
1
NBP 50, NBP 100 2
NBP 200 3
Optional mud rings, UL Listed junction boxes, external junction boxes, and surface mounting boxes are available
for use with the button panels. Read any installation instructions and UL guidelines that come with the mounting
devices, then install the box or mud ring in the opening at the installation site.
To prepare the site:
1. Using the size of the junction box or mud ring for reference, cut the hole in the mounting surface. Protect the
surface prior to and during cutting so the surface is not damaged.
NOTES:
The approximate cutout dimensions for an Extron-supplied two-gang mud ring are 4.1" W x 3.75" H
(104 mm W x 95 mm H).
If mounting the NBP 100 directly to the mounting surface, cut a hole of approximately 3.6" W x 2.9" H
(91 mm W x 74 mm H).
2. Run cables to the mounting location, leaving enough slack for
device installation.
3. Install the junction box or mud ring into the wall or
furniture.
4. Secure the cables with a clamp for strain
relief and so they do not slip back down into
the wall or furniture.
Rev. F: Added
references to
the NBP VC1/2
models.
Wall
Mud Ring
Figure 11. Installing a Mud Ring