NAV SD 121 Scaling Decoder and NAV D 121 Decoder • Installation and Basic Operation 7
Control Connector wiring
Figure 5 shows how to wire the Control (RS-232 and IR) connector.
SG
RxTx Gnd
IR Device
RS-232 Device
RS-232 IR
Tx Rx SGG
Figure 5. Control Connector Wiring
NOTES:
The RS-232 Tx and Rx line pair must cross once between this connector and the destination.
The length and preparation of exposed wires is important. The ideal length is 3/16 inch (5 mm).
If the stripped section of wire is longer than 3/16 inch, the exposed wires may touch, causing a short
circuit.
If the stripped section of wire is shorter than 3/16 inch, wires can be easily pulled out even if tightly
fastened by the captive screws.
Do not tin the wires before installing them in the connector. Tinned wires are not as secure in the
connector and could be pulled out.
Digital I/O Connector wiring
Figure 6 shows two examples of how to wire the Digital I/O connector to:
Monitor events such as a switch or sensor (example1)
Power LEDs or other devices that accept a TTL signal functions (example 2)
DIGITAL I/O
12G
DIGITAL I/O
12G
Example 1 Example 2
Switch,
Sensor
2
1
G
Heat
Shrink
Over
Shield
Wires
(Switches, sensors,
LEDs, relays, or
similar items)
Ground
Share the same ground among
I/O connections.
Device 2
Device 1
Wire
Nut
Figure 6. Digital I/O Connector Wiring Examples