Extron IPL EXP S5 handleiding

49 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 24 van 49
IPL EXP I/O Series • Hardware Features and Installation 16
1 2 12V24V G3 4 12V24V G
+V OUT / DIGITAL I/O
5 6 12V24V G7 8 12V24V G
12 VDC / 24 VDC
19W MAX TOTAL
12V
24V
G
21
12 VDC and 24 VDC Power Output
Use these ports to power accessories such as occupancy sensors.
Total maximum output is 19 watts, if a PoE+ power supply is used to
power the IPL EXP RIO8. These ports are always on, unless the total
load reaches the overload condition.
Global Congurator software provides a way to monitor these ports.
Normal operation mode —The load drawn by connected devices
is 0 - 17 watts.
Limit mode —The total load on these ports is between 17 and 19
watts.
Overload mode — The load has reached or exceeded 19 watts.
All power output ports shut off. Power is restored after you correct
the excessive power draw from the connected devices.
Sensor, LED,
accessory,
or similar item
Sensor, LED,
accessory,
or similar item
12V
G
24V
G
Heat
Shrink
Over
Shield
Wires
Rear Panel, IPL EXP RIO8
Ground
Share the same ground among
I/O connections.
Device 2 digital I/O
with 24 VDC
Device 1 digital I/O
Wire
Nut
IPL EXP RIO8
1 2 12V24V G3 4 12V24V G
RELAYS
3
4
7
8
1
2
5
6
+V OUT / DIGITAL I/O
5 6 12V24V G7 8 12V24V G
12 VDC / 24 VDC
19W MAX TOTAL
LAN / PoE+
G
G
G
Ground
Digital
Input
Ground
Power
24 VDC
Power
12 VDC
Occupancy
Control Output
Ceiling
Ceiling Tile
Hanger Clip
Extron
OCS 100C
Occupancy
Sensor
Extron
IPL EXP RIO8
Expansion Interface
LAN/PoE
LAN
Extron
ECM S10 Rx
Receiver does not detect
signal from transmitter.
ECM S10 Tx
Partition closed
Figure 6. Wiring the DC Power Output Ports
Can add this once the device is shipping:
IPL EXP RIO8
1 2 12V24V G3 4 12V24V G
RELAYS
3
4
7
8
1
2
5
6
+V OUT / DIGITAL I/O
5 6 12V24V G7 8 12V24V G
12 VDC / 24 VDC
19W MAX TOTAL
LAN / PoE+
Ground
Digital Input 1
Digital Input 2
Ground
Power
24 VDC
Power 12 VDC
Occupancy
Control Output
Ceiling
Ceiling Tile
Hanger Clip
Extron
Occupancy
Sensor
Extron
IPL EXP RIO8
Expansion Interface
LAN/PoE
LAN
Extron
Room
A
vailability
Indicator
6

Bekijk gratis de handleiding van Extron IPL EXP S5, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkExtron
ModelIPL EXP S5
CategorieNiet gecategoriseerd
TaalNederlands
Grootte7534 MB