IPCP Pro Series • Hardware Features and Installation
15
IPCP Pro PCS1-Specific Front Panel Features
Power button (switch) and LED
The front panel power button (switch) provides a convenient way to manually turn
switched AC power output on or o󰀨 for the rear panel AC power output cable on the IPCP Pro PCS1.
NOTE: The button is not a safety disconnect device. In case of an emergency, disconnect AC
power from the power input (appliance inlet) of the connected equipment.
The IPCP Pro PCS1 can be congured (using Global Congurator or ControlScript programming software)
to monitor the power output condition and to alert users in the event of a power fault interruption. The
IPCP Pro PCS1 can be set up to monitor the circuit breaker and also the current load at the switched AC power
output port.
NOTE: The power output state setting persists after a power cycle.
The AC power LED on the IPCP Pro PCS1 lights to indicate the power output state as follows:
Lit green: Power output is enabled.
Off (dark): Power output is disabled.
Lit red: A fault condition is detected, and power output is disabled.
Front panel lockout (executive mode)
To prevent unauthorized use, the power button can be locked (disabled) via a front panel lockout mode (executive
mode) that can be enabled or disabled by one of two methods:
Using software, as part of the configuration or when programming actions, monitors, or schedules
Pressing and holding down the
Power
button for 3 seconds
The power LED blinks three times to indicate the lockout mode has been enabled or disabled.
When the front panel is locked, if the
Power
button is pressed, the power LED blinks three times to indicate that
the button is locked, and the unit does not change power states as a result of the button press.
NOTE: The executive mode state (on or off) persists after and is retained during a power cycle.
Circuit breaker
The front panel features a 10 A rated circuit breaker. When a fault condition occurs,
the breaker is triggered, which stops power output. This condition can be monitored and the system
can be congured (using available commands) to send an alert e-mail or perform some other action.
After you correct the cause of the overcurrent condition, press the
Breaker
button to manually reset
the circuit breaker.
NOTES:
The circuit breaker and the
Reset
button are not affected by front panel lockout (executive mode)
settings.
The embedded web page for the unit displays the state of the circuit breaker and the value of the
combined current load.
IR Learning Receiver
In most cases, Extron has already produced a driver le for controlling the projector, display, or source device you
plan to use. If a device driver le is not available, you can create your own using Extron IR Learner Pro software,
the remote control of the projector or display, and the IR learning receiver sensor on the non-embedded IPCPs.
NOTE: The IPCP embedded control processors and IPCP Pro PCS1 do not have an IR learning sensor.
The IR learning receiver accepts infrared signals from 30 kHz to 300 KHz. The IR remote control must be pointed
directly at the receiver for best results. The front panel diagrams (see the bottom of gure 8 on page 13 and the
right side of gure 9 on page 14) indicate the best distances and angles (15 degrees o󰀨 axis from the receiver) at
which to hold the remote control.
POWER
Rev. M: Changed
Global Scripter
to ControlScript
programming
software per latest
terminology.
Rev. M: Removed
“and is retained
during “ from
the note about
the power output
after a power
cycle.
10
BREAKER
10
P
R
E
S
S
T
O
R
E
S
E
T
When an overcurrent condition occurs, such as a short
circuit or circuit overload
Rev. L: Added text about
the current load and
circuit breaker state
being shown on the
embedded web page.