IPCP Pro Series • Hardware Features and Installation
10
Each control processor comes with a factory-installed Secure Sockets Layer (SSL) security certificate.
If you intend to install a different SSL certificate, contact your IT department to obtain the certificate or
for instructions on how to obtain one (see Secure Sockets Layer (SSL) Certificates on page 59 for
requirements and guidelines regarding SSL certificates).
For systems that will use IEEE 802.1X security, obtain a PEM-encoded security certificate and private key
(see IEEE 802.1X Certificates on page 59) from your IT department.
Mount and Cable All Devices
Mount the unit to a rack or furniture (see Mounting the IPCP Pro Series on page 16).
Cable devices to the control processor (see Ports, Addressing, and Connections starting on page 19).
Connect power cords and power on all the devices.
Set Up the Control Processor, Touchpanels, and Network Button Panels for Network
Communication
For models without AV LAN ports: Connect the PC that you will use for setup, the LAN port of the control
processor, and the touchpanels or network button panels to the same Ethernet network. For control processor
LAN connections, see LAN (IP) connectors and LEDs on page 28.
For models with AV LAN ports: Connect the PC that you will use for setup, the control processor, and the
touchpanels or network button panels to the Ethernet network. For control processor AV LAN connections,
see AV LAN connectors and LEDs on page 28.
Start Toolbelt and use it to set the IP address or addresses, subnet, gateway IP address, DHCP status, and
related settings (see the flowchart in Network Communication Setup on page 12).
NOTES:
When setting up DHCP during network configuration or if using a host name instead of an IP address,
the user must enter a qualified host name
(
Username.HostName.Domain
). For example:
somename.extron.com
.
A dedicated AV LAN safeguards AV systems from outside intrusion or interference by separating
device control and other network traffic from a corporate or campus network. To ensure that the
control processor LAN and AV LAN connections (ports) are connected to separate networks, the LAN
and AV LAN IP address schemes must be on different subnetworks.
Rev. K, 04/2019: added a checklist item
for the 802.1X certificate and key.
Rev. J: Added references
to network button panels.
Rev. J: Added references
to network button panels.
Rev. J: Added note about
putting LAN & AV LAN
onto separate subnets.