FOX3SR 301 and FOX3SR311 Scaling Receivers • SIS Configuration and Control 23
Using verbose mode
SSH connections to a FOX3 device can be used to monitor for changes that occur on the
device, such as SIS commands from other SSH sockets or a serial port. For a SSH session
to receive change notices from the device, the SSH session must be in verbose mode 1 or
3 (see the SIS command Verbose mode on page28).
Simple Instruction Set Control
Host-to-Unit Instructions
SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command character sequence. When a command is valid, the
receiver executes the command and sends a response to the host device. All responses
from the receiver to the host end with a carriage return and a line feed (CR/LF = ]), which
signals the end of the response character string. A string is one or more characters.
Device-Initiated Power-Up Message
When the device completes its start‑up, it issues the following message to the host:
© Copyright 20yy, Extron FOX3 SR 301 (311) MM (SM), Vx.xx, 60nnnnnn
20yy is the copyright year
Vx.xx is the firmware version number
60nnnnnn is the part number.
NOTE: This message only displays if the FOX3 device is connected to the serial port.
Error Responses
When the scaling receiver receives a valid SIS command, it executes the command
and sends a response to the host device. If the scaling receiver is unable to execute the
command because the command is invalid or it contains invalid parameters, the scaling
receiver returns an error response to the host. The error response codes are:
E10 — Invalid command E21 — Invalid room number
E11 — Invalid preset number E22 — Busy
E13 — Invalid parameter E24 — Privilege violation
E14 — Invalid for this configuration E25 — Device not present
E17 — Invalid command for signal type E26 — Maximum number of connections
exceeded
E18 — System or command timed out E28 — Bad file name or file not found
Timeout
Pauses of 10 seconds or longer between command ASCII characters result in a timeout.
The command operation is aborted with no other indication.