Extron DTP T UWP 4K D Series • Installation and Operation 10
Power supply voltage polarity is critical. Incorrect voltage polarity can damage
the power supply and the unit. The ridges on the side of the cord (see figure 7 on
previous page) identify the power cord negative lead.
La polarité de la source d’alimentation est primordiale. Une polarité incorrecte
pourrait endommager la source d’alimentation et l’unité. Les stries sur le côté du
cordon permettent de repérer le pôle négatif du cordon d’alimentation.
To verify the polarity before connection, plug in the power supply with no load and
check the output with a voltmeter.
Pour vérifier la polarité avant la connexion, brancher l’alimentation hors charge et
mesurer sa sortie avec un voltmètre.
The length of the exposed (stripped) copper wires is important.
The ideal length is 3/16 inch (5 mm). Longer bare wires can short together.
Shorter wires are not as secure in the connectors and could be pulled out.
La longueur des câbles exposés est primordiale lorsque l’on entreprend de les
dénuder. La longueur idéale est de 5mm (3/16inches). S’ils sont un peu plus
longs, les câbles exposés pourraient se toucher et provoquer un court circuit. S’ils
sont un peu plus courts, ils pourraient sortir, même s’ils sont attachés par les vis
captives.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air
handling spaces or in wall cavities.
Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une
utilisation dans les espaces d’aération ou dans les cavités murales.
RS-232 Connector Wiring
NOTE: Do not tin the wires before installing them in the direct insertion connector.
Tinned wires are not as secure in the connectors and could be pulled out.
Remote RS-232 and Contact Closure Connector
Wire the rear Remote RS-232 and contact closure connector as shown in figure 8.
Ground
Receive pin on connected unit
Transmit pin on connected unit
Connected RS-232 and
Contact Closure Device Pins
Tx/Rx
Pins
Pin 1 f
or contact closure control
Pin 2 f
or contact closure control
RxTx
RS-232 Contact
21
G
REMOTE
Figure 8. RS-232 and Contact Closure Connector Wiring
Over DTP RS-232 Connector
Wire the rear Over DTP RS-232 connector as shown in figure 9.
Tx Rx G
OVER DTP
Ground
Receive pin on connected unit
Tr
ansmit pin on connected unit
Figure 9. Over DTP Connector Wiring