Extron DTP T HD2 4K 230/330 • Installation and Operation 6
F
RS-232 Over TP port — To pass bidirectional serial control between
DTP-compatible or HDBaseT-compatible devices, connect a control device
to the 5-pole captive screw connector. This port includes only the 3 poles
labeled “RS-232” (see image below for wiring instructions).
IR Over TP port — To transmit and receive IR signals, connect a control
device to the 5-pole captive screw connector. This port includes only the
2 poles labeled “IR” and shares the ground pole with the RS-232 port
(see image below for wiring instructions).
Tx/Rx
Pins
Rx GTx
RS-232 IR
RxTx
TxRx
RxTx
Gnd
Gnd
IR Device
RS-232 Device
NOTE: RS-232 and IR data can be transmitted simultaneously.
IR
Tx Rx G Tx Rx
RS-232
IR
Tx Rx G Tx Rx
RS-232