Extron ACP VC1 EU handleiding

8 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 4 van 8
4
ACP VC1 EU/MK • Setup Guide (Continued)
Setting the Bus ID Address
Each ACP device in a system must have a unique six-digit binary bus ID. ACP bus
IDs are set using the DIP switch assembly on the rear panel of the
ACP VC1 EU/MK (see
E
on gure 1 at the beginning of the guide).
Switch 1 on the left sets the most signicant bit (highest number, 32) while switch
6 on the right sets the least signicant bit (the lowest number, 1). See the example
addresses to the right.
Step 5: Cable All Devices
1. Connect the ACP panel to the host device.
2. Connect ACP panels to each other if multiple panels are used in the system
(see the wiring diagram below for correct wiring).
NOTES:
Wire both ends of each ACP cable the same. Connectors are
interchangeable between the host device and ACP devices.
Do NOT power an ACP panel from more than one power source.
3. Apply power to the host device after correctly cabling all devices.
Cabling
Attach cables using the diagram below as a guide. Wiring is the same for all ACP
models. Connect a 4-pole captive screw connector to each end of the cable,
wiring both ends the same. In most cases, ACP devices are powered by the host
device. Power is carried on the V+ pin of the ACP VC1 EU/MK and other ACP
devices.
Extron STP20-2/1000 or STP20-2P/100 cable is recommended for ACP device
connections.
ACP devices that are relatively far from the host device can be connected to an
optional Extron PS 1220EB eBUS power inserter or an Extron 12 VDC desktop
power supply as shown in the diagrams below and on the next page (see the ACP
VC1 EU/MK Specications at www.extron.com to determine if additional power is recommended).
Example Addresses
Bus ID
(Decimal)
Binary
Address
DIP Switch
Setting
0 000000*
*Reserved
(for controller
address)
1 2
3
4
56
ON
M
S
B
L
S
B
BUS ID
1 000001
1 2
3
4
56
ON
M
S
B
L
S
B
BUS ID
2 000010
1 2
3
4
56
ON
M
S
B
L
S
B
BUS ID
3 000011
1 2
3
4
56
ON
M
S
B
L
S
B
BUS ID
4 000100
1 2
3
4
56
ON
M
S
B
L
S
B
BUS ID
5 000101
1 2
3
4
56
ON
M
S
B
L
S
B
BUS ID
6 000110
1 2
3
4
56
ON
M
S
B
L
S
B
BUS ID
7 000111
1 2
3
4
56
ON
M
S
B
L
S
B
BUS ID
8 001000
1 2
3
4
56
ON
M
S
B
L
S
B
BUS ID
G
-
S
+S
+V
Ground
+ Signal
-
Signal
+12 VDC
Black
and
Drains
Green
White
Red
G
-
S+S
+V
Drain Wires
Basic ACP Connector Wiring

Bekijk gratis de handleiding van Extron ACP VC1 EU, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkExtron
ModelACP VC1 EU
CategorieNiet gecategoriseerd
TaalNederlands
Grootte1713 MB

Caratteristiche Prodotto

Kleur van het productBlack, White
Gewicht100 g
Gewicht verpakking200 g
Breedte verpakking102 mm
Diepte verpakking178 mm