5. To remove the button, press the button backward through its slot in the button
plate until the membrane containing the button is free (see 1 in the figure to the
right).
6. To replace the button, align the two pegs in the button membrane with the
holes located at opposite corners of the empty slot on the back of the button
faceplate and push the button forward so it fits in the slot (
2
). Ensure the
button text orientation is correct.
7. Align the button plate with the metal mounting plate using the pegs on the rear
of the button plate as guides.
8. Snap the button plate into place.
9. Reattach the plastic faceplate using the two screws removed in step 1 on the
previous page.
Step 4: Set Bus ID Address
Set the bus identication (bus ID) DIP switches for the ACP VC1 D and any other
ACP panels being connected to the system. Each ACP device must have a unique
bus ID. If multiple panels have the same bus ID, address conicts may cause one
or more of the panels to not be recognized in DSP Congurator or by the
host device. Up to eight ACP devices can be connected in the same system.
+V
G
+S
-S
+V
G
+S
-S
ACP
PWR LOAD = 1.5W
STATUS
GREEN
AMBER
RED
LINK
COM ERROR
ID ERROR
+
V
+
S G
–
S
010010
ON
123456
000001
1
ON
123456
18
Unit address
DIP switches
Binary address
ACP port on a
DMP 128 Plus, or
on another ACP
endpoint
ACP Ports
• Connect up to eight (8) ACP endpoint devices per
DMP 128 Plus.
• Wire the connectors the same at both ends.
• These ports are identical. You can connect devices
interchangeablly to either port.
• Do not exceed a total of 1000 feet (305meters) of cable for
connections between the DMP 128 Plus and all of the ACP
panels.
• Power is provided by the IPCP Pro, a PS 1220EB power
inserter, or an Extron 12 VDC power supply.
Bus ID Address DIP Switches
• Use these DIP switches to set the six-bit, binary
bus address for the ACP 100.
• Each ACP connected to the same DMP 128 Plus
must have a unique address.
• Switch 1 (on the left) is the highest value (32, the
the most signicant bit [labeled “MSB”]).
• Switch 6 (on the right) is the lowest (1, the least
signicant bit [labeled “LSB”]).
• Up = on = 1, Down = off = 0
Examples:
22
MUTE
11