Extech TKG150 handleiding

84 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 76 van 84
ExtechInstruments
76TKG100_TKG150UltrasonicThicknessGaugeUserGuidev2.811/13
7 Technical Specifications
Specifications for the TKG100/TKG150 Ultrasonic
Thickness Gauges
Size:5"(127mm)(L)x3"(76.2mm)(W)x1.25"(31.75mm)(H)
Weight:8OZ(.23kg)
Thicknessrange:0.008‐20inches(0.20mm‐508mm),dependingon
material,temperatureandtransducerselection
Materialvelocitycalibrationrange:0.2000.7362in/μS(0.50818.699
mm/μS)
Temperature:GaugeOperating:‐Fto122°F(20°Cto50°C)Surface
temperatureofmaterial:Dependingonprobeused,from‐Fto1000°
F(20°Cto537°C)
Batterylife:Upto200hours(40hourswithbacklighton)
Batterytype:2"AA"Alkaline
Display:128X64GraphicsLCDmonochrome
Informationdisplays:LOS,min,max,largereadingwhiledisplayingmin
atthesametime,velocity,zero,calibration,units,freeze,unfreeze,%
batteryliferemaining,gain‐low,std,high,echotoechosymbol
(option)
Resolution:0.001"(0.01mm),0.01"(0.1mm)
Accuracy:BasicAccuracyis0.004”butoncleansmoothsteelan
accuracyof0.001”isnotuncommon.Themorecorrosivethe
environment,andpittedthesurfaceundertest,theclosertothe0.004”
accuracyonecanexpecttobe.Asnoted,ahigheraccuracycanbe
obtainedwhenmeasuringoncleaner
steel.
Proberecognition:Viapicklistfromamenu
Delaylinezeromeasurement:Autoatpowerupwithlistednumeric
value.Idealforcorrectingdelaylinewear/curvatureandfortransducer
acousticdriftatelevatedtemperatures
Package:Custom,splashproof,highimpactplasticwithrubber,
illuminatingkeypadforgo/nogotesting
Bandwidth:0.520MHz(3dB)
Units:English/Metric/Microseconds
Gain:Low,StandardandHighforvaryingtestconditions
Measurementrate:4/secand20/secinfastmode

Bekijk gratis de handleiding van Extech TKG150, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkExtech
ModelTKG150
CategorieNiet gecategoriseerd
TaalNederlands
Grootte8314 MB