3.3 Jumper Settings
3. Layout, Connections & Jumper Settings
JP2
ENA
DIS
ON HOST
JP1
Default:
JP2 = ENA
JP1 = ON
Settings Status Function
Jumper JP2 Jumper JP1 Netzteil Host PC Hub Downstream
Bus Power Host control Data Power
ENA ON
on off
no on
off on yes on
DIS ON
on off
no on
off on no off
ENA HOST
on off no off
off on yes on
DIS
on off no off
HOST
off on no off
DIS/ENA HOST/ON on on yes on
The two internal jumpers Bus Power (JP2) and Host Control (JP1) can be used to configure the
power output on the downstream ports as required.
The possible settings and their effects are shown in the following table.