6 | PENTAIR EZ-RO INSTALLATION AND OPERATION GUIDE FOODSERVICE.PENTAIR.COM
INSTALLATION REQUIREMENTS
This product is for commercial use only and must be installed and maintained in accordance with manufacturer’s
guidelines and local regulatory plumbing and electrical codes.
LOCATION
The system should be installed indoors and close to:
• Electrical outlet (120vac, 60hz) with space for one
plug (within ve feet of tank)
• RO processor: The atmospheric tank can be no
further than 10 feet from the RO processor due to
the tubing connections and solenoid cable.
• Water source
• Drain (within ve feet of unit)
• Equipment served
Do not let the processor or storage tank freeze or be
exposed to rain or direct sunlight.
WATER REQUIREMENTS
Feed Water
Adequate ow and pressure of water to the unit is
essential.
Water supply should be:
• Cold water only. Tempered water up to 80°F (26.7°C)
can be used.
• Minimum 50 psi dynamic pressure, maximum 100 psi
static pressure.
• Supplied by a dedicated 1/2" water line to the
installation.
Install a full-ow ball valve and pressure gauge with 1/2"
female pipe thread (user supplied) for connection to
installation hardware provided with the system.
Feed-water Chemistry
Operating a system on water supplies outside of these
parameters may lead to premature membrane failure.
Feed TDS Up to 1000 ppm
Feed pH 5 - 10
Hardness <12 grains
Free chlorine <3.0 mg/l
Turbidity <1.0 NTU
Iron (Fe) <0.1 mg/l
Manganese <0.05 mg/l
Hydrogen sulde 0.0 mg/l
Silica <20 mg/l
A water analysis must be conducted before installing
the system, or the required information can be obtained
from your local water utility. If your water analysis shows
that any of these parameters are not within range,
additional pretreatment and/or higher frequency of
maintenance may be necessary. Contact your Everpure
distributor for assistance.
The membrane can be fouled by:
• Silica
• Flocculants such as alum or cationic polymers
• Hardness, iron, manganese and hydrogen sulde
The presence of silica or occulants in the feed water may
require special chemical pretreatment or more frequent
membrane replacing. Please note that membrane failure
due to fouling is not covered by the warranty.
DRAIN
The drain should:
• Be located within ve feet of the unit
• Have a locally compliant air gap
The drain must:
• Allow a minimum ow of two gallons per minute
• Be accessible for system set-up and service
STORAGE TANK
The tank must be located 10 feet or less from the water
processor unit. The oor beneath the storage tank
should be smooth, clean and free of sharp objects that
could scratch or puncture the bottom of the tank.
OPTIMIZED WATER LINES TO EQUIPMENT
Tubing, piping and associated ttings connecting
optimized water lines to equipment should be food
grade material that meets NSF Standards 51 or 61 with a
minimum pressure rating of 100 psi.
Optimized water may react with most metal piping
imparting a bad taste. Plastic pipe or reinforced opaque
beverage tubing are acceptable choices for optimized
water distribution. A 1/2" or larger inside diameter
tubing or hose will minimize pressure drop.