Start-up Switches
The BD600+ has operations which are used in the factory to prepare the unit to be shipped. Each oper-
ation is performed by turning on the unit while holding down a button until the version number mes-
sage goes away. Some of them may post a “do you want to..” type message, with the WAIT AND
EXIT button blinking to indicate “yes” and the REBUILD button lit steadily to indicate “no.”
Restore Factory Defaults - PANIC button
This function restores all configuration values to the factory defaults. In the event of serious system
malfeasance, this function should be tried, and if it does not restore normal behavior, do the following
to clear memory.
Clear all Memory RAMP TO ZERO button
This function clears all memory and returns the unit to the state at which it left the factory.
Perform Production Self-Test - SNEEZE button
This function goes into a series of self tests. Many of these tests cannot pass unless loop-back connect-
ors are installed on audio and control connectors. These tests should only be run under instruction
from Eventide as some of them can erase internal programs.
Other Functions
The remaining front panel keys are unused at this time or are reserved for factory purposes.