4 burner models: set the burner pressure to 2.75kPa for ULPG, set
the burner pressure to 1kPa for Natural Gas. For commissioning of
the appliance with the regulator for Natural Gas, the test point
pressure should be 1.00kPa with all burners operating on HIGH.
Apply a manometer to the test nipple and reset the regulator if
necessary. Do not forget to replace the test nipple screw and to leave
the instruction book with the user.
Test point for ULPG gas
WARNING:
This appliance has to be installed as per AS/NZS 5601 and if a hose
connectino is made, hose assembly must:
1) Be certified as conforming with AS/NZS 1869, and be Class B or
Class D.
2) Diameter 10mm (minimun).
3) Length 1000mm (maximum).
WARNING:
Ensure hose assembly is restrained from accidental contact with
the flue outlet of an under bench oven.
The hose assembly should be kept clear of the floor when the
appliance is in the installed position.
Test point for Natural gas