10
ADJUSTING THE BURNER MINIMUM FLAME HEIGHT:
NOTE: This adjustment can only be performed by the installer or an authorised service personnel.
The minimum burner flame is factory adjusted for the gas type stated on the gas type label adjacent to the gas
connection and should not require adjustment. Adjustment may be required if the hotplate has been converted
from Natural gas to Universal LPG or vice versa.
GAS CONVERSION INSTRUCTIONS:
The manufacturers servicing instructions detail how authorised personnel may convert the hotplate from Natural
gas to Universal LPG or from Universal LPG to Natural gas. Contact the manufacturer or agent as required.
For model ECT60WCXECT600GSECT60GX
ADJUSTED FOR NATURAL GAS 1.0kPa
ADJUSTED FOR ULPG 2.75KPa
NOZZLES
DIAMETER
mm
Gas consumption,
MJ/h
NOZZLES
DIAMETER
mm
Gas consumption,
MJ/h
WOK 1.70 13.0 WOK 0.98 13.0
Rapid 1.40 9.5 Rapid 0.90 10.0
SEMI RAPID 1.10 6.0 SEMI RAPID 0.7 6.75
AUXILIARY 0.90 4.5 AUXILIARY 0.55 4.0
Replacement of the nozzles must be performed by a
qualified person. Once the nozzles have been replaced
this label must to be affixed to the name plate of the
appliances.
Replacement of the nozzles must be performed by a
qualified person. Once the nozzles have been
replaced this label must to be affixed to the name
plate of the appliances.
Natural Gas regulator is to be fitted and adjusted
Change the NG regulator to LPG by a qualified
person.
For model ECT900GX. ECT900GX2,ECT900GX3
ADJUSTED FOR NATURAL GAS 1.0kPa
ADJUSTED FOR ULPG 2.75KPa
NOZZLES
DIAMETER
mm
Gas consumption,
MJ/h
NOZZLES
DIAMETER
mm
Gas consumption,
MJ/h
WOK 1.70 13.0 WOK 0.98 13.0
Rapid 1.40 10.0 Rapid 0.90 10.0
SEMI RAPID 1.10 6.0 SEMI RAPID 0.7 6.3
AUXILIARY 0.90 4.0 AUXILIARY 0.55 4.0
Replacement of the nozzles must be performed by a
qualified person. Once the nozzles have been replaced
this label must to be affixed to the name plate of the
appliances.
Replacement of the nozzles must be performed by a
qualified person. Once the nozzles have been
replaced this label must to be affixed to the name
plate of the appliances.
Natural Gas regulator is to be fitted and adjusted
Change the NG regulator to LPG by a qualified
person.