If you set a temperature lower than the current room temperature, the radiator will remain
inactive and wait for the temperature to drop. If you set a higher temperature, it will start
heating immediately, and the B9 heating indicator will light up on the display.
Selecting the Heating Mode
After setting the temperature, select the heating power using the B2 button:
• H1 – Low Power (1000 W)
• H2 – Medium Power (1500 W)
• H3 – High Power (2500 W)
• AF (Anti-Frost) – Maintains a fixed temperature of 7°C (cannot be changed)
The display will show the selected mode for a few seconds and then save it automatically.
The appliance automatically switches between heating and standby mode based on the set
temperature. Once the target temperature is reached, the radiator will turn off and restart
when the room temperature drops below the set value.
Timer and Heating Schedule
Press the B5 timer button to activate the automatic shutdown function. Use the "+" and "–"
buttons to set the operating time between 1–24 hours. After a few seconds, the value will
be saved automatically, and the countdown will start. The B8 indicator will appear on the
panel. When the timer reaches "00," the radiator will automatically turn off. To cancel the
timer, set the value back to "00."
Note
• The weekly heating schedule can only be set via the ETA Smart app, where you can
program heating by the hour for the entire week.
Display Brightness Adjustment
The brightness of the display can be adjusted using the B6 button in the following
sequence: 100% > 50% > 25% > Complete Off (control symbols remain visible).
Note
• If no button is pressed for 1 minute, the display brightness will automatically decrease
by 50%.
Child Lock
Press and hold the "+" and "–" buttons for 3 seconds to activate the child lock. The B11
lock symbol will appear on the display, and the controls will be locked. To deactivate the
child lock, press and hold the same buttons again for 3 seconds.
Turning Off the Radiator
Press the B1 button to turn the radiator off into standby mode. To turn it off completely,
switch off the A1 main power switch on the appliance body. If the radiator is not in use with
a set timer or remote control via the app, unplug it from the power socket after use.