For example (Fig. 9):
a1 = 1.937m
b1 = 1.689m
so the difference (d) is a1 – b1 = 0.248.
BA
30 m
a1
a1-b1=d
b1
d
Figure 9
Place the device at a distance of 1m from rod A. Measure the height of the rod A (value a2 in Fig. 10). Calculate the following
equation: b2' = a2 – d. Then, measure the height of rod B (b2). If the deviation between b2' and b2 is over 3mm, the crosshairs
should be calibrated.
For example:
a2 = 1.724m
d = 0.248
so b2' is: a2 – d = 1.476
a2
a2-d=b2’
BA
1 m
b2
d
Figure 10
Take off the eyepiece cover (12). Turn the adjusting screw with the pin (Fig. 11) until the values b2' and b2 are the same. Put on
the eyepiece cover again.
Figure 11
Specifications
Magnification 32x
Working distance 120m
Height accuracy for individual measurement 1.6mm/30m
Standard deviation per 1km double leveling 1mm
Objective aperture 36mm
Image erect
Field of view 1°30'
Close focus 0.3m
Compensator range ±15'
Compensator setting accuracy ±0.3"
Multiplication factor 100
Additive constant 0
Horizontal circle graduation 1° or 1 gon
Accuracy of the bubble level 8'/2mm