Start-up
The “5 safety rules” to be used:
Disconnect from mains; Safeguard from switching on
again; Check tha
t system is deenergised; Earth and short
circuit; Cover or cordon o neighbouring live parts;
Select suitable tool, measuring equipment and, if neces
-
sary, personal safety equipment;
Evaluation of measuring results;
Selection of electrical installation material for safeguard
-
ing shut-o conditions;
IP protection types;
Installation of electrical installation material;
Type of supply network (TN system, IT system, TT system)
and the resulting connecting conditions (classical zero
balancing, protective earthing, required additional meas
-
ures etc.).
Installation may only take place in normal com-
mercial switch boxes (device boxes) in accord-
ance with DIN 49073-1.
Please observe the hazard information in section
„2 Hazard information“ on page 50 during in-
stallation.
Permitted cable cross sections for connecting to the wall
thermostat are:
rigid cable
[mm
2
]
flexible cable with/without ferrule
[mm
2
]
0.75 – 1.50 0.75 – 1.50