10
CAUTION
airflow. Ventilation is highly recommended if mounted in an enclosure.
Installation procedures:
Step 1: Determine the installation location and heat-dissipation space
Figure2-1 Mounting
Step 2
Connect the system in the order of battery -- load --PV array following Figure 2-2,"
Schematic Wiring Diagram," and disconnect the system in the reverse order.
Figure 2-2 Wiring Diagram
CAUTION
Please do not connect the circuit breaker or fast-acting fuse during the wiring
and ensure that the electrode polarity is correctly connected.
A fast-acting fuse whose current is 1.25 to 2 times the controller's rated current
must be installed on the battery side with a distance from the battery no longer