16
3) Setting the battery parameters by MT50
Connect the controller to the remote meter (MT50) through a standard network cable. After selecting the
battery type as "USE," set the voltage parameters by the MT50. Refer to the MT50 manual or aftersales
engineer for details.
4. Local set the battery parameters
Operation:
Step1: Press and hold the ENTER button to enter the battery type interface on the battery voltage
interface.
Step2: Press the SELECT button to change the battery type, such as selecting the "GEL," and then
press the ENTER button to confirm and go back to the battery voltage interface automatically.
Step3: On the battery voltage interface, press and hold the ENTER button to enter the battery type
interface again.
Step4: Press the SELECT button to change the battery type to the "USE." Under the "USE" battery type,
the battery parameters can be set via the LCD.
Parameters
Default
Range
Operation Steps
System voltage level
(SYS)
12VDC
12/24
VDC
1) Under the "USE" interface, press the ENTER
button to enter the "SYS" interface.
2) Press the ENTER button again to display the
current "SYS" value.
3) Press the SELECT button to modify the
parameter.
4) Press the ENTER button to confirm and enter
the next parameter.
Boost charging voltage
(BCV)
14.4V
9~17V
5) Press the ENTER button again to display the
current-voltage value.
6) Press the SELECT button to modify the

Bekijk gratis de handleiding van EPEVER Tracer 1206AN, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.