Up to 6 controllers connection in parallel to expand the system
Load dry contact to control the external load switch
To set the first and the second disconnection voltage of load by the software
Auto-control of utility and generator dry contact design to compose a hybrid power system easily
Remote temperature and voltage sensor design to collect more accurate battery
temperature/terminal voltage and eliminate the battery cables' voltage drop
Isolated RS485 communication ports (Modbus protocol)
5V/200mA RS485 communication ports with short circuit protection
Support remote monitoring and parameters setting via the APP or PC software
★ The parameters are measured in the Tracer10415AN@48V system.
1.2 Characteristics
Figure 1 Product Characteristics
❶ Charging indicator
❿ (Utility/Generator) dry contact ON interface
❷ SELECT button
⓫ RBVS interface
(4)
❸ External fuse
⓬ (Load) dry contact interface
(5)
❹ Grounding terminal
⓭ (Utility/Generator) dry contact OFF
interface
❺ Screw hole(M4)
⓮ PV terminals
(6)
❻ (PV reverse polarity) alarm indicator
⓯ Battery terminals
(6)