Step1: Determine installation location and heat-dissipation space
Determination of installation location: The controller shall be installed in a place with
sufficient air flow through the radiators of the controller and minimum clearance of
150mm from the upper and lower edges to ensure natural thermal convection.
CAUTION: Ensure that the controller is able to dissipate heat if it’s installed in a
closed area. If the controller is to be installed in an enclosed box, it is important to ensure
reliable heat dissipation through the box.
Step2: Wiring
❶❷❸
Connect the system in the order ofStarter batteryBATT2 →❷Main battery BATT1
→❸PV array in accordance with the above diagram anddisconnect the system in the
reverse order❸❷❶.
CAUTION: The BATT1 and BATT2 must be set at same voltage level, and other
situations are not supported for the moment.
CAUTION: Follow the above instruction for wiring, otherwise, it may cause the BATT2
system voltage identification error.