S-PLAY LITE (70094)
Visit the ENTTEC website for the latest version.
..
USER MANUAL
26 |
ID: 5950188
Document Updated: April 2024
Art-Net
An Art-Net trigger can be unicast or broadcast to the S-PLAY LITE.
The Trigger will be activated, when the incoming value is
equal or greater than the Art-Net channel parameters
defined.
To avoid clashes do not use a universe assigned for
Recording/Playback.
When used in a playlist, the S-PLAY LITE will wait to receive
the Trigger below before continuing.
sACN
The Trigger will be activated, when the incoming value is equal
or greater to the sACN channel parameters defined.
To avoid clashes do not use a universe assigned for
Recording/Playback.
When used in a playlist, the S-PLAY LITE will wait to receive
the Trigger below before continuing.
DMX
The Trigger will be activated, when the incoming value is
equal or greater to the DMX settings defined.
To avoid clashes do not use a universe assigned for
Recording/Playback.
When used in a playlist, the S-PLAY LITE will wait to receive
the Trigger below before continuing.
Note: If DMX is selected as output protocol in the setting page,
the DMX triggers will be disabled in the playlist.
Button
S-PLAY LITE’s reset button can be configured as a trigger button
to activate a playlist command.
A Trigger will be activated when the button is on release
or on press.