GB | 12
• A3 – Screen child lock
• Can be set to 0 or 1.
• 0 = lock o.
• 1 = lock on.
• The default value is 0.
• A4 – Status of the device after reconnecting to power after a power outage
• Can be set to 0, 1 or 2.
• 0 = same status as before the outage.
• 1 = thermostat o.
• 2 = thermostat on.
• The default value is 0.
• A5 – Thermostat screen brightness in standby mode
• Can be set to 0, 1 or 2.
• 0 = screen o.
• 1 = room temperature is slightly illuminated on the screen.
• 2 = room temperature is strongly illuminated on the screen.
• The default value is 2.
• A6 – Calendar Mode selection for Weekly Mode
• Can be set to 0, 1 or 2.
• 0 = 5+2 (Mo–Fr + Sa + Su).
• 1 = 6+1 (Mo–Sa + Su).
• 2 = 7 days.
• The default setting is 0.
• A7 – Minimum temperature setting
• Can be set to between 1 °C and 10 °C.
• The default setting is 5 °C.
• A8 – Maximum temperature setting
• Can be set to between 20 °C and 70 °C.
• The default setting is 35 °C.
• A9 – Low-temperature protection
• Can be set to between 1 °C and 10 °C or turned o completely.
• The protection is turned o by setting the value to 10 °C and pressing the arrow. Two dashes will
appear on the screen.
• The default setting is 5 °C.
• AA – High-temperature protection of the external sensor
• Can be set to between 20 °C and 70 °C or turned o completely.
• The protection is turned o by setting the value to 20 °C and pressing the arrow. Two dashes will
appear on the screen.
• The default setting is 45 °C.
• AB – Setting the limit of the sensor’s high-temperature protection
• Can be set to between 1 °C and 9 °C.
• The default setting is 2 °C.
• AC – Open Window function (temperature)
• Can be set to between 10 °C and 20 °C or turned o completely.
• The function is turned o by setting the value to 10 °C and pressing the arrow. Two dashes will
appear on the screen.
• The default setting is o.
• AD – Open window function (interval)
• Can be set to between 10 and 20 minutes.
• The default value is 10 minutes.
• AE – Reset
• Ao is shown on the screen. To reset to factory settings, hold the button for 5 seconds.