ES5 Series -Trouble Shooting
Trouble Shooting
1.
A. Con rm electric cord is securely plugged in.
B. Con rm receptacle is energized—reset breaker or repair house wiring.
WARNING: The following checks thru 7.A.1. should be done with electric cord
removed from receptacle.
C. Con rm continuity in 3-conductor cord—replace if defective.
D. Con rm continuity in single pole, single throw Power Switch (the two adjacent terminals are
switch terminals and the remote terminal is a tie-terminal). Replace if defective.
______________
2.
A. Con rm continuity of Thermostat—replace if defective.
B. Con rm continuity of Heating Element—replace Steam Generator Casting if defective.
C. Con rm Thermal cuto .
______________
3.
A. Defective light in switch— replace entire switch.
______________
4.
A. All Models: Clogged water nozzle, water inlet or strainers—check and clean as required,
see Maintenance and Service sections.
B. Models ES5M, ES5M18, ES5MT, ES5CTS, ES5CTS18, ES5PBS, ES5PBS18 & ES5PBST:
Water pan empty— ll pan.
C. Model ES5M & ES5M18: Con rm pump is operative—check valves—inlet hose must not
leak.See Service section. Rebuild or replace as required.
D. Models ES5PB, ES5PB18, ES5PBT, ES5CT & ES5CT18:
1. Con rm Water Shut-O Valve is on and Water Hose Assembly is properly hooked
up. Refer to #3 from the Installation section page 2. A quick way to con rm water line
is operational is to disconnect Water Hose at quick disconnect tting and push a small
probe into quick disconnect tting—water should ow freely.
2. Con rm continuity of Water Solenoid Valve—replace if defective.
E. Models ES5CT, ES5CT18, ES5PB, ES5PB18, ES5PBT, ES5PBS, ES5PBS18, ES5PBST,
ES5CTS & ES5CT18: Con rm continuity of Steam Push Button Switch when depressed—
replace if defective.
F. Models ES5CTS, ES5CTS18, ES5PBS, ES5PBS18 & ES5PBST:
1. Con rm continuity of Oscillating Pump—replace if defective.
2. Con rm integrity of hoses and ttings. Any and all leakage must be eliminated.
______________
5.
A. Models ES5CT, ES5CT18, ES5PB, ES5PB18 & ES5PBT: Water Solenoid Valve seat
dirty—clean or replace as required.
______________
6.
A. Models ES5CT, ES5CT18, ES5CTS & ES5CTS18: Con rm continuity of light replace if
defective.
______________
__________________________________________
1. Unit Does Not Heat
Switch On, Light Out
!
2. Unit Does Not Heat
Switch On, Light On
3. Unit Heats
Switch on, Light Out.
4. Unit Heats Up,
But Does Not Steam—
No Water Evident on,
Light Out.
5. Unit Floods—
Switch On
6. Unit Works—
Ready Light Inoperative

Bekijk gratis de handleiding van EmberGlo ES5PBS, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkEmberGlo
ModelES5PBS
CategorieNiet gecategoriseerd
TaalNederlands
Grootte2432 MB