1 Content
Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany
Sensor KNX AQS/TH-UP Touch • from application 1.1
Status: 02.08.2022 • Technical changes and errors excepted.
1. Safety and operating instructions ....................................................... 5
2. Description ........................................................................................... 5
3. Commissioning .................................................................................... 6
3.1. Addressing the equipment ...................................................................................... 6
4. Display and operation at the device .................................................... 7
4.1. Mode display and manual temperature controller ................................................ 7
4.2. Change ambient temperature with the buttons .................................................... 8
5. Transfer protocol ............................................................................... 10
5.1. List of all communications objects ....................................................................... 10
6. Parameter setting .............................................................................. 21
6.1. Behaviour on power failure/ restoration of power .............................................. 21
6.2. General settings ..................................................................................................... 21
6.3. Temperature value ................................................................................................. 21
6.4. Temperature threshold values .............................................................................. 22
6.4.1. Threshold value 1, 2, 3 ............................................................................... 22
6.4.1.1. Threshold value ............................................................................ 22
6.4.1.2. Switching output .......................................................................... 23
6.4.1.3. Block .............................................................................................. 24
6.5. Temperature PI control .......................................................................................... 24
6.5.0.1. General control ............................................................................. 24
6.5.1. General set point values ............................................................................. 26
6.5.1.1. Set point Comfort ......................................................................... 27
6.5.1.2. Standby setpoint ........................................................................... 28
6.5.1.3. Eco setpoint ................................................................................... 28
6.5.1.4. Setpoint values for frost/heat protection (building protection) 29
6.5.1.5. General control variables ............................................................. 29
6.5.2. Heating control level 1/2 ............................................................................. 30
6.5.3. Cooling control level 1/2 ............................................................................. 32
6.6. Humidity measurement ......................................................................................... 34
6.7. Humidity threshold values .................................................................................... 34
6.7.1. Threshold value 1, 2 ................................................................................... 35
6.7.1.1. Threshold value ............................................................................ 35
6.7.1.2. Switching output .......................................................................... 36
6.7.1.3. Block .............................................................................................. 36
6.8. Humidity PI control ................................................................................................ 37
6.8.0.1. General control ............................................................................. 37
6.8.0.2. Controller setpoint ........................................................................ 38
6.8.0.3. Dehumidification and/or humidification ..................................... 39
6.9. Dewpoint measurement ........................................................................................ 40
6.9.1. Cooling medium temp. monitoring ........................................................... 40
6.9.1.1. Threshold value ............................................................................ 40
6.9.1.2. Switching output .......................................................................... 41