Installation manual
35
9.2 Electrical connections
WS6–8
Electrical connections
Heating alternative Main voltage Hz Heating power
kW
Total power
kW
Recommended
fuse
A
Electric heated 220-240V 1/1N~ 50/60 3.0/5.4/7.5 3.3/5.7/7.8 16/25/32
220-240V 3~ 50/60 3.0/5.4/7.5 3.4/5.7/7.8 10/16/25
380-415V 3N/3~ 50/60 3.0/5.4/7.5 3.4/5.7/7.8 10/10/16
440V 3~ 50/60 5.4/7.5 5.7/7.9 10/16
480V 3~ 60 5.4/7.5 5.7/7.9 10/16
Non heated/Steam heated 208-240V 1/1N~ 50/60
1
0.4 10
380-480V 1~
2
50/60
1
0.4 10
1. Total power and recommended fuse does not depend on the heating power in those cases.
2. Prepared for 3~
WS6–9
Electrical connections
Heating alternative Main voltage Hz Heating power
kW
Total power
kW
Recommended
fuse
A
Electric heated 220-240V 1/1N~ 50/60 3.0/5.4/7.5 3.3/5.7/7.8 16/25/32
220-240V 3~ 50/60 3.0/5.4/7.5 3.4/5.7/7.8 10/16/25
380-415V 3N/3~ 50/60 3.0/5.4/7.5 3.4/5.7/7.8 10/10/16
440V 3~ 50/60 5.4/7.5 5.7/7.9 10/16
480V 3~ 60 5.4/7.5 5.7/7.9 10/16
Non heated/Steam heated 208-240V 1/1N~ 50/60
1
0.4 10
380-480V 1~
2
50/60
1
0.4 10
1. Total power and recommended fuse does not depend on the heating power in those cases.
2. Prepared for 3~
WS6–11
Electrical connections
Heating alternative Main voltage Hz Heating power
kW
Total power
kW
Recommended
fuse
A
Electric heated 220-240V 1/1N~ 50/60 3.0/7.5/10.0 3.5/7.9/10.4 16/35/50
220-240V 3~ 50/60 3.0/7.5/10.0 3.5/7.9/10.4 16/25/32
380-415V 3/3N~ 50/60 3.0/7.5/10.0 3.4/7.9/10.4 10/16/20
440V 3~ 50/60 7.5/10.0 7.9/10.4 16
480V 3~ 60 10.0 10.4 16
Non heated/Steam heated 208-240V 1/1N~ 50/60
1
0.8 10
380-480V 1~
2
50/60
1
0.8 10
1. Total power and recommended fuse does not depend on the heating power in those cases.
2. Prepared for 3~
WS6–14
Electrical connections
Heating alternative Main voltage Hz Heating power
kW
Total power
kW
Recommended
fuse
A
Electric heated 220-240V 1/1N~ 50/60 3.0/7.5/10.0 3.5/7.9/10.4 16/35/50
220-240V 3~ 50/60 3.0/7.5/10.0 3.5/7.9/10.4 16/25/32
380-415V 3/3N~ 50/60 3.0/7.5/10.0 3.4/7.9/10.4 10/16/20
440V 3~ 50/60 7.5/10.0 7.9/10.4 16
480V 3~ 60 10.0 10.4 16
Non heated/Steam heated 208-240V 1/1N~ 50/60
1
0.8 10
380-480V 1~
2
50/60
1
0.8 10
1. Total power and recommended fuse does not depend on the heating power in those cases.
2. Prepared for 3~