Electrolux TD6-30LAC handleiding
Handleiding
Je bekijkt pagina 26 van 46

26
Installation manual
7.5 Test run
Note!
Before test run the machine, ensure that the air flow/static back pressure has been adjusted accorded to the
"Evacuation system" section. Adjust the air flow if necessary.
• Loosen the measuring branch screw (2) 1/4 turn; connect a manometer to the measuring branch and make sure
the connection is tight to prevent air leakage.
• Connect the power to the machine and select a program with heat.
• Start the machine.
• Check that the nozzle pressure is correct according to the gas type, see "Table of pressure and adjustment”.
• If the nozzle pressure should be adjusted:
– Demount the cover screw (3).
– Turn the screw (4). Clockwise: increasing nozzle pressure.
– Turn the screw (4). Counter Clockwise: decreasing nozzle pressure.
• Check that the gas is burning evenly. The blue flame on the burner is preferred.
4
3
2
fig.X03504
• Remount the cover screw (3).
• Remove the manometer and tighten the screw (2) when the adjustments are done.
Note!
After connection all joints must be checked. There must not be any leaks.