3.12 Adjusting the minimum gas
level on the hob burner
1. Disconnect the appliance from the
electricity.
2. Remove the knob for the hob. If there is
no access to the bypass screw dismount
the control panel before adjustment start.
3. With a thin and flat screwdriver adjust the
bypass screw A.
The model determines the position of the
bypass screw A.
A
A
Changing from natural gas to liquid
gas
1. Fully tighten the bypass screw.
2. Put the knob back.
Changing from liquid gas to natural
gas
1. Unscrew approximately one turn the
bypass screw position A.
2. Put the knob for the hob back.
3. Connect the appliance to the electricity.
WARNING!
Put the mains plug into the mains
socket only if all parts are back into
their initial position. There is a risk of
injury.
4. Light the burner.
Refer to "Hob - Daily use" chapter.
5. Turn the knob for the hob to the minimum
position.
6. Remove the knob for the hob again.
7. Screw on slowly the bypass screw till the
flame becomes minimum and stable.
8. Put the knob for the hob back on.
3.13 Oven injector replacement
1. Remove the bottom plate of the oven
cavity A to get access to the oven burner
B.
AB
2. Release the screw C, which keep the
burner in position.
C
3. Carefully move the burner off the injector
support D.
D
E
F
4. Slowly move it to the left side. Make sure
that the burner bush stays on the burner
mouthpiece. Do not apply force to the
wire of the spark plug connector F and to
the thermocouple conductor E.
ENGLISH 11