05306004
Page
Notice
Date
INSTALLATION
MANUAL
9
6
1004
D1142
D0460
5 x A
A
5 x A
Connection of the ironer evacuation systeme
It is essential that the diameter of the evacuation pipe should be
selected as a function of each installation so that the pressure loss
never exceed 206 Pa (value measured at ambient temperature).
6. Installation/
Putting into service
Fresh air inlet
To allow the machine to work at ist best,
it is important that the laundry air inlet
passes throught an opening from the
outside.
The fresh air arrival must be equivalent to
the volume of evacuated air (référez vous
au débit des ventilateurs à pression nulle
dans les caractéristiques techniques).
Note: in the case of several machines,
these values should be added together.
In the case of a machine with gas
heating, it is essential that the rooms
should be ventilated.
In order to prevent drafts in the room, the
best solution is to place the air inlet
behind the machine.
The free section* of the air inlet must be
five times greater than the section of the
evacuation pipe.
*(The free section corresponds to the
unrestricted air passage surface area
through the grill).
Do not forget to allow for the fact that
grills often occupy half the total area of
the free air opening.
Evacuation duct
It is recommended that a separate
smoothwalled evacuation duct should be
connected to each machine, providing the
least possible resistance to air.
Check that the shaft flow is at least twice
the capacity of the blower output.
These conditions are ABSOLUTELY
ESSENTIAL for correct working of the
ironer.