Safety
Natural Gas
If the pressure is too low, ignition failure and/or slow drying times may result. Excessively high supply
pressure will result in erratic operation of the gas valves internal pressure regulator. Further information in
section: Gas connection.
Propane Gas
Dryers made for use with propane gas have the gas valve pressure regulator blocked open, so that the
gas pressure must be regulated upstream of the dryer. In accordance with American Gas Association
(AGA) standards, a gas pressure regulator, when installed indoors, must be equipped with a vent limiter or
a vent line must be installed from the gas pressure regulator vent to the outdoors. The water column
pressure must be regulated at the source (propane tank), or an external regulator must be added to each
dryer. Further information in section: Gas connection.
Piping/Connections
The dryer is provided with a 1/2” or a 3/4” N.P.T. inlet pipe connection extending out the rear area or
through the top of the dryer. For ease of servicing, the gas supply line of each dryer should have its own
shut-off valve.
The size of the gas supply line (header) will vary depending on the distance this supply line travels from
the gas meter or, in the case of propane gas, the supply tank, the number of tees, other gas-operated
appliances, etc. Specific information regarding supply line size should be determined by the gas supplier.
NOTE:
Undersized gas supply piping can create a low or inconsistent gas pressure which will
result in erratic operation of the burner ignition system.
Consistent gas pressure is essential at ALL gas connections. It is recommended that a 3/4- inch pipe gas
loop be installed in the supply line serving the bank of dryers. An in-line pressure regulator must be
installed in the gas supply line (header) if (natural) gas line pressure exceeds 12-inches water column
pressure.
IMPORTANT:
The information regarding the settings of the water column pressure for Natural gas
dryers and Propane gas dryers is found in section: Gas connection. The pressure is
required at the gas valve pressure tap of each dryer for proper and safe operation.
A 1/8” N.P,T. plugged tap, accessible for test gauge connection, must be installed in the main gas supply
line immediately upstream of each dryer.
IMPORTANT:
Pipe joint compounds that resist the action of natural gas and propane gas MUST BE
used.
WARNING:
Test ALL connections for leaks by brushing on a soapy water solution (liquid detergent
also works well). NEVER TEST FOR GAS LEAKS WITH AN OPEN FLAME.
ALL components / materials must conform to NATIONAL FUEL GAS CODE specifications. It is important
that gas pressure regulators meet applicable pressure requirements and that gas meters are rated for the
total amount of appliance BTU’s being supplied.