Electro-Voice Evid 4.2T handleiding
Handleiding
Je bekijkt pagina 25 van 32

EVID-S8.2/EVID-S8.2T speakers
EVID-S8.2 EVID-S8.2T
Frequency response (-3 dB): 70 Hz – 20 kHz
1
70 Hz – 20 kHz
1
Frequency response (-10 dB): 50 Hz – 20 kHz
1
50 Hz – 20 kHz
1
Sensitivity: 90 dB
2
90 dB
2
Max SPL (calculated): 110 dB (116 dB Peak)
Coverage angle: Horizontal 90°, Vertical 90°
Power handling: 90 W (360 W Peak) Continuous Pink Noise (100 hours)
Low Z: Yes Yes
Nominal impedance: 8 Ω
Minimum impedance: 6.4 Ω
Recommended High-Pass 50 Hz
Input transformer (70 V/100 V): No 60 W
Transformer taps: N/A 7.5 W (70 V Only), 15 W, 30
W, 60 W
LF transducer: 8 in (203 mm)
HF transducer: 1 in (25 mm)
Connectors: Captive screws on wall bracket
Removable locking 4-pin connector (Euroblock) – (2) for
connection to additional speakers in a distributed line
Max. wire size 12AWG (2.5 mm)
Environmental: IP54 (per IEC-60529)
Color: Black or white
Dimensions (HxWxD): 390 mm x 250 mm x 224 mm (15.4 in x 9.8 in x 8.8 in)
3
Net weight: 5.1 kg (11.3 lb) 5.8 kg (12.8 lb)
Shipping weight (pair): 13.0 kg (28.7 lb) 14.8 kg (32.6 lb)
Included hardware: Mounting bracket and 5-mm Allen wrench
Packaged quantity: 2
1
Half space (wall mounting).
2
Half space (on wall) averaged 100 Hz – 10 kHz, 1 W.
3
Without brackets.
6.3
en 25
Electro-Voice Installation manual 2017.08 | 01 | F.01U.345.360
Bekijk gratis de handleiding van Electro-Voice Evid 4.2T, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Electro-Voice |
Model | Evid 4.2T |
Categorie | Speaker |
Taal | Nederlands |
Grootte | 3664 MB |