Electro-Voice EVA-SG2 handleiding

44 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 34 van 44
34 en | Rigging-strength ratings and safety factors EVA Expandable Vertical Array
2023-01 | 04 | F01U196199
Installation manual
Electro-Voice
4. The suspended column must be perpendicular (plumb) to within ±5 degrees.
5. If suspending a spreader bar or grid from two points, the angle between those two
suspension lines must not exceed 60° (maximum 30° from plumb each).
6. Never exceed 760lb (345kg) total column weight when using the EVA-CG coupler grid
(discontinued). When flying EVA-1151D modules (discontinued) behind EVA-2082S full-
range modules on the EVA-CG coupler grid, the maximum number of EVA-2082S full-range
modules at the front of the grid is five and the maximum number of EVA-1151D
subwoofer modules (discontinued) at the rear of the grid is three. A bottom pull-up is not
allowed when using the EVA-CG. Flying a single column from the EVA-CG is not allowed.
Refer to
Structural rating charts, page 34
.
60º MAX
+5º
MAX
_
Figure8.1: Left: side-to-side simplified structural-rating guidelines for EVA arrays (angle shown
exaggerated for illustration purposes). Right: front-to-back angular pull structural-rating guidelines for EVA
spreader bars
60º
MAX
Figure8.2: Side-to-side angular pull structural-rating guidelines for EVA spreader bars
8.5 Structural rating charts
!
Warning!
Use only the listed combinations.

Bekijk gratis de handleiding van Electro-Voice EVA-SG2, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkElectro-Voice
ModelEVA-SG2
CategorieNiet gecategoriseerd
TaalNederlands
Grootte3734 MB