Please Note:
When the 8-Step is set to fast tempos, a high setting for the GLIDE parameter
may yield a sequence that does not change very much from one step to the next. How GLIDE
reacts can depend on the tempo of the sequence.
Adjusting the Depth Parameter
The Depth parameter adjusts the total output level of the sequence from 0 (no output) to 9
(maximum output). An output setting of 8 is equivalent to 100% Depth. A setting of 9 is
110% but it will not increase the output from sliders set to the maximum level any further,
it will only increase the output of sliders set below maximum.
1.
Ensure that you hear the 8-Step sequencing an external device. Adjusting the
DEPTH parameter is only apparent when you hear the sequencer acting on another
device.
2.
Press and release the MODE knob until all three mode LEDs are lit. When all three
mode LEDs are lit, the 8-STEP is set to DEPTH mode.
3.
Turn the MODE knob to change the DEPTH setting. Turning MODE Counter-
clockwise will decrease the DEPTH setting, turning clockwise increases the DEPTH
setting.
Changing Play Modes: Loop, 1-Shot and Step-Thru
There are three available Play modes:
Loop
mode continuously loops the sequence from
beginning to end and back to the beginning again.
1-Shot
mode goes through the entire
sequence one time with each press of the PLAY FSW.
Step-Thru
mode removes the 8-
STEP’s internal tempo and goes through the sequence, one step at a time, each time you
press the PLAY FSW. In Step-Thru mode, the sequence loops back to the beginning when
you come to the end of the sequence.
1.
Play mode is changed by pressing and holding the PLAY FSW for three seconds.
2.
After three seconds of holding the PLAY FSW, the display will temporarily display
the mode that it just changed to. It displays
L
for Loop,
1
for 1-Shot and
t
for
Step-Thru. It will show the new Play Mode for 1.5 seconds, and then go back to
whatever it was previously displaying.
3.
After the PLAY mode has changed, release the PLAY FSW. To change the PLAY
mode again, press and hold the PLAY FSW for another 3 seconds.
4.
You must release the PLAY FSW between PLAY mode changes before you can
change the PLAY mode again.
Using the RESET Footswitch
1.
Each time you press the RESET FSW, the sequence starts over with its first step.
2.
If Direction is set to Forward or Bounce, pressing the RESET FSW will cause the
sequence to jump to Step 1.
3.
If Direction is set to Reverse, pressing the RESET FSW will cause the sequence to
jump to the maximum step set by the Sequence Length parameter. For example,
5
when Direction equals Reverse and Sequence Length is set to 8, pressing the
RESET FSW forces the sequence to jump to Step 8.
4.
Pressing the RESET FSW while the sequence is currently playing back does not
pause the sequence, it forces the sequence to start over and then keeps going.
5.
Pressing the RESET FSW while the sequence is paused, forces the current step to
jump back to the start of the sequence but it does not begin playing the sequence
back.
6.
If the 8-STEP is playing its sequence and is synced to either MIDI Clock or External
CV Clock, when you press the RESET FSW it will not immediately restart the
sequence, instead it waits for its current step to finish and then restarts the
sequence on the next step, doing this helps the 8-STEP remain in sync with the
external tempo control.
Using an Expression Pedal with the 8-STEP
1.
Connect the plug from your Expression pedal into the jack labeled EXP IN on the
right side of the 8-STEP. A list of acceptable expression pedals include: Electro-
Harmonix Expression Pedal, Boss
®
FV-500L, M-Audio
®
EX-P, Moog
®
EP-2, Roland
®
EV-5 or another 8-STEP PROGRAM. You may also connect Control Voltage to the
EXP IN jack with a TS cable, the acceptable control voltage range is 0V to 5V.
2.
The EXP. MODE button, located between the RESET and PLAY FSWs, selects the
function for the expression pedal to modulate. The functions include: RATE,
DEPTH, GLIDE, SEQuence LENGTH and off (no LEDs lit). External CV Clock may
also be selected with the EXP. MODE button but we will talk more about this in a
later section.
3.
For this example, choose RATE, which is the tempo of the expression pedal. Each
time you press and release the EXP. MODE button, the 8-Step will select the next
mode, then cycle back to RATE.
4.
Moving the expression pedal from the heel to toe position will increase the rate of
the tempo. The heel position is a slow rate, the toe position is equal to the setting
of the RATE slider.
5.
If you have tapped in a tempo, your tap tempo will be at the heel of the expression
pedal. As you move the pedal forward the tempo increases.
6.
Now press the EXP. MODE button to modulate DEPTH. As you move the expression
pedal, the overall amplitude of the sequence changes. Toe yields the largest
amplitude.
Using the 8-STEP as an Expression Pedal Thru
1.
Connect the plug from your Expression pedal into the jack labeled EXP IN on the
right side of the 8-STEP.
2.
Stop the sequence by pressing the PLAY FSW.
3.
Reset the sequence by pressing the RESET FSW.
4.
Press and release the EXP. MODE button until the DEPTH setting is selected.