TROUBLESHOOTING
Do not repair or disassemble the air conditioning. Unqualified repair will invalidate the warranty and may lead to failure, causing
injuries and property damage. Only use it as directed in this user manual and only perform operations advised here.
Problems
Reasons
Solutions
The air
conditioner does
not work.
There is no electricity.
Turn it on after connecting it to a socket with electricity.
The display shows "E4".
Discharge the water inside.
The ambient temperature is too low or
too high.
Only use the machine within the temperature range of 7-
35⁰C (44-95⁰F).
In cooling mode, the room temperature
is lower than the desired temperature.
Change the desired temperature.
In dry mode, the ambient temperature
is low.
The ambient temperature must be above 16 ⁰C.
(60 ⁰F).
The cooling
effect is not good
There is direct sunlight.
Use curtains to reduce the direct sun heat.
Doors or windows are open; there are a
lot of people; or in cooling mode, there
are other sources of heat (e.g. fridges)
Close doors and windows; increase air conditioning power
The filter screen is dirty.
Clean or replace the filter screen.
The air inlet or outlet is blocked.
Clear obstructions: make sure venting is correct as
described in this user manual and the hose is not bent
Loud Noise
The air conditioning is not placed on a
flat surface.
Put the air conditioning in a flat, hard place (to reduce
noise). Correct any venting issues.
The compressor
does not work.
Overheat protection starts.
Wait 3 minutes until the temperature is lowered, then
restart the machine. Correct any venting issues.
The remote
control does not
work.
The distance between the machine and
the remote control is too far.
Let the remote control get close to the air conditioner and
ensure that the remote control directly faces the receiver.
The remote control is not aligned with
the receiver.
Batteries are dead.
Replace batteries.
Others
No refrigerant or there is minimal
refrigerant.
Refer to Service Centre (check leakage, wielding, vacuum
pump, charge refrigerant according to nameplate)
Anti-freezing protection
Waiting for defrosting.
The function will recover automatically. No user input is
needed.
High-pressure protection
After the inside gas pressure comes down, it will function
normally. No user input is needed.
If problems not listed in the table occur or recommended solutions do not work, please get in touch with
the service centre.
ERROR CODES
CODE
CAUSE
SOLUTION
dH
Unit in dry mode
It's not a fault; no action is required.
E2 Room temperature sensor error
The room temperature is outside the operational
range. Do not operate until the room is within the
range required.
E4
Water full alarm
Empty the water tank
E5 Temperature sensor error
Check the route of the vent pipe to ensure it is not
constructed.
MODE
LIGHT
FLASHING
Cool/dry mode: the compressor has not
started, and the mode light will flash.
This is normal
The unit will start operation when the protection
period has finished (approx. 3 minutes)