9
INSTALLATION
This unit must be installed on an external wall, as it vents
directly out of its rear.
Only install the unit on a flat, solid, reliable wall capable of
supporting its weight. Ensure that there are no cables, pipes,
steel bars or other obstructions behind the wall.
Leave at least 10 cm of space to the left and right of the
machine. At least 20cm of space must be left above the unit
to help the air flow smoothly. A minimum distance of 50cm is
advised from the front of
the unit.
Paste the supplied installation template paper in position on the
wall, ensuring that the reference line is level using a spirit level.
The hole for the drainage pipe must be drilled using a 25mm Drill bit.
Ensure the hole is at a downward angle (min 5 degrees) so that the
water will drain correctly. It is recommended to insulate any parts of
the drain pipe which is accessible to prevent the build up of ice when
running at low temperatures.
Use a 180 or 182mm core drill to drill the two holes for the
units ventillation, ensuring that both the holes are aligned
with the template.
Use the template to mark the position of the screws for the
hanging rail, using a spirit level to ensure it is straight and
level.
Drill the marked holes using a suitable 8mm drill bit and
insert wall plugs. Line the hanging rail with the holes, and
fix the rail into position using the supplied screws.
Ensure that the hanging rail is securely fastened onto the
wall, and that there is no risk of the unit tipping or falling.