UNDERSTANDING THE FUNCTIONS
18
IMPORTANT INFORMATION
HEATING MODE
When the air conditioner is placed in heating mode, the indoor unit will appear to be inactive while it
follows its pre-heat procedure to heat the evaporator coils. Once the coils have heated, the indoor fan
will start to run. This process usually takes 1 – 3 minutes, and is designed to ensure that cold air is not
circulated.
During heating mode, the appliance can automatically activate a defrost cycle, which is essential to clean
the frost on the condenser so as to recover its heat exchange function. This procedure usually lasts for 2-
10 minutes. During defrosting, the fan in the indoor unit will stop operation. After defrosting, it will return
to HEATING mode automatically.
AUTO RESTART
The air conditioner will automatically restart when electricity is restored after a power cut. If in doubt,
check the settings.
RANGE OF INTERNAL THERMOSTAT
The internal thermostat can be set at a desired temperature between 16 and 31°C. Note that whether the
desired value is achieved depends on the room size, temperature and insulation of the room.
RANGE OF HEAT PUMP FUNCTION
The heat function can be used when the external ambient temperature is above -20°C. The performance
of the heat pump will degrade with lowering external temperatures. Please note the performance will
reduce when the outdoor temperature drops below 5°C.
CAPACITY
The required cooling or heating capacity depends greatly on the location and/or use of the room where
the air conditioner is installed. Strong sunlight and the presence of people, lights or equipment creates an
additional heat load. Normal living spaces require about 350 Btu per square meters of floor surface. In
strong sunlight or if other sources of heat are present, this may be as much as 1200 Btu per sqm.
Tip: On warm days, let the air conditioner cool the room as much as possible during the night and keep
the temperature constant from night to daytime.
SELECTING THE OPERATIONAL MODE
This is a multi-split system and multiple indoor units are connected to a single outdoor compressor. Please
make sure that the indoor units are set to operate in the same mode. Multiple indoor units connected to
the same compressor cannot operate in different modes at the same time although you are able to set
different target room temperatures for each unit. Fan only mode can be operated while other units are in
heating or cooling.