INFORMATION REGARDING THE INSTALLATION OF THE INDOOR UNIT
INSTALLING THE REAR PANEL
1. Always mount the rear panel horizontally.
Due to the water tray within the indoor unit
we would advise that the outlet of the water
tray should be fractionally lower when
installing as this will aid drainage of the
condensate collected.
2. Fix the rear panel on the wall with screws.
3. Be sure that the rear panel has been fixed
firmly enough to withstand the weight of an
adult (60Kg), furthermore the weight should
be evenly shared by each screw.
INSTALLING THE PIPING HOLE
1. Make the piping hole (55mm diameter) in the
wall at a slight downward slant to the outdoor side (To aid
drainage of the condensate).
2. Insert the piping-hole sleeve into the hole to
prevent the connecting piping and wiring from been
damaged when passing through the hole.
The piping can be lead out on
the right, left or directly behind
the indoor unit as seen in fig. 1.
Please cut off the pipe hole
guards if you are changing the
pipe position. The unit also
features alternative guards for
more pipe positioning.
Make sure that the drain pipe is
underneath the pipelines.
(Fig.3) (When the drain pipe
passes the room interior, some
condensed water might occur to
its surfaces if the humidity is
very high).
Tidy up the copper pipes,
electrical cables and water
drains and pass them through
the wall hole drilled earlier
(fig.2).
Hang the mounting slots of the
indoor unit on the wall mounting
bracket making sure is tight in place (fig.3) so that the hooks at the bottom of the indoor unit
match the hooks of the wall mounting bracket (fig.4)