INSTALLING WITHIN A BATHROOM
If the appliance is to be fitted within a bathroom, a good understanding of the
zoning within bathrooms is required to ensure the unit is mounted in a safe position.
The appliance is rated as IPX4 and should be installed outside of Zones 0 -2. We
would advise when the unit is fitted within a bathroom, the plug is removed from
the unit, and a suitable fused spur is installed in accordance with BS 7671. In
addition, when used in a bathroom, it must be protected by a suitable RCD to
prevent the risk of electric shock.
Zone 0:
The interior of the bathtub or shower basin.
Zone 1:
The area around the bathtub or shower basin up to a height
of 2.25m above the floor
Zone 2:
The area stretching to 0.6m outside the bath or shower and
above the bath or shower if over 2.25m