Operating Condition
Please operate air conditioner in the correct conditions as following.
COOL mode operation
DRY mode operation
Outdoor temperature should be in range of 16°C
to 43°C.
Room humidity should be lower than 90%.
Otherwise, it is possible for air conditioner to
gather frost on the air conditioner surface
causing condensation. This is normal if unit is
operating outside the range.
Outdoor temperature should be in range of -7°C
to 24°C.
Power requirement
Rated voltage and voltage range: 230V ~ ± 10%
• The electric components will be damaged when the voltage is too high. If the
voltage is too low, the compressor will vibrate violently and damage the refrigerant
system and cause the compressor and electric components to malfunction.
The ground must be connected.
• Special socket must be used. Furthermore, the socket and wiring must
conform to the wiring regulations. And the earthing method must be reliable.
• In fixed circuit, there must be electricity leakage protection switch of enough
power capacity and air switch with enough space.