Vision Color 250™
©Elation Professional® 31 Vision Color 250™
– This function controls the automatic lamp start feature. By default the unit will
automatically ignite the lamp when unit is turned on. Use this function to turn this
feature on and off.
1. Access the main menu.
2. Tap the UP button until “SPEC” is displayed, press ENTER.
3. Tap the UP button until “LAAU” is displayed, press ENTER.
4. The display will show “ON/OFF.”
5. Press the UP button to display “ON” to activate this function, or “OFF” to
deactivate this function.
6. Press ENTER to confirm.
7. Press MODE/ESC to return to the main menu.
RDMX
– This function allows the DMX address to remotely be adjusted from a DMX
console. This setting requires special settings for both the controller and the fixture.
RDMX is on by default. Follow the procedure listed below to access the RDMX
functions:
Fixture Settings:
1. Access the main menu.
2. Tap the UP button until “SPEC” is displayed, press ENTER.
3. Tap the UP button until “RDMX” is displayed, press ENTER.
4. The display will show “ON/OFF.”
5. Press the UP button to display “ON” to activate this function, or “OFF” to
deactivate this function.
6. Press ENTER to confirm.
7. Press MODE/ESC to return to the main menu.
Controller Settings:
1. Set the DMX value of channel 1 to a value of 7.
2. Set the DMX value of channel 2 to a value of 7 or 8. When channel 2 is set to "7"
you can adjust the starting address between 1 and 255. When set to "8" you can