39
ERROR CODES
Error Codes subject to change without notice
ERROR CODES DESCRIPTION
Pan
Movement is not located in the default position after the reset.
These messages will appear after a 󰤱xture reset if the magnetic-indexing
circuit malfunctions (sensor failed, or magnet is missing) or there is
a motor failure (defective motor or a defective motor IC drive on the
main PCB). This error may also be displayed if the head/yoke was blocked
during a reset function.
Tilt
Cyan
Movement is not located in the default position after the reset. These
messages will appear after a 󰤱xture reset if the magnetic-indexing
circuit malfunctions (sensor failed, or magnet is missing) or there is a
motor failure (defective motor or a defective motor IC drive on the main
PCB).
Magenta
Yellow
CTO
ColorWheel
RotGobo
GoboRot
FixedGobo
Animation
AnimationRot
Focus
Zoom
Prism1
Prism1Rot
Prism2
Prism2Rot
Blade
LED Fan1
These messages will appear if there is a temperature and/or fan
malfunction.
LED Fan2
LED Fan3
LED Fan4
LED Fan5
LED Fan6
GoboFan
Blade Fan
HeadFan1
HeadFan2
BaseFan1
BaseFan2
LedTemp
BaseTemp