ERROR CODES
When power is applied, the fixture automatically enters a “Reset/Test” mode. This
mode brings all the internal motors to a home position. If there is an internal problem
with one or more of the motors an error code will flash in the display in the form of
“Err channel is XX” were as XX will represent a specific function. The display may
show one or multiple error codes. For example, when the display shows “Err Channel
is Pan Movement”, it means the Pan Yoke is not in the home position. If there are
multiple errors at the same time, you may see the error messages “Err Channel is Pan
Movement”, “Err Channel is Tilt Movement” flash for 2 times.
If errors occur during the initial start-up procedure the fixture will self-generate a
second reset signal and try to realign all the motors and correct the errors. If any
errors persist after a second attempt a third attempt will be made. If after a third
attempt all the errors have not been corrected the fixture will make the following
determinations:
3 or More Errors - The fixture cannot function properly with three or more errors
therefore the fixture will place itself in a stand-by mode until subsequent repairs
can be made.
Less Than 3 Errors - The fixture has less than 3 errors; therefore most other functions
will work properly. The fixture will attempt to operate normally until the errors can
be correct by a technician. The errors in question will remain flashing in the
display as a reminder of internal errors.
PAN- Movement Er (PAN-Yoke Movement Error)
This message will appear after the reset of the fixture if the yoke’s magnetic-indexing
circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective
(or its driving IC on the main PCB). The PAN- movement is not located in the default
position after the reset.
TILT- Movement Er (TILT-Head Movement Error)
This message will appear after the reset of the fixture if the head’s magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective
(or its driving IC on the main PCB). The TILT- movement is not located in the default
position after the reset.