13 PRO FS 15R FOLLOWSPOT™ User Manual Ver 1
5. Insert NEW lamp securely until it sits flush against the lamp holder, and is seated in
the same proper position as the OLD lamp.
Note: The lamp will only fit one way.
NOTE: Wrap NEW lamp with the soft cloth that comes with the packaging; AVOID
naked hand contact to the lamp directly.
6. Once NEW lamp has been properly installed, attach the (2) RED WIRES to the
base of the lamp.
7. Replace the rear cover plate back (see image below) into place by securing (3)
screws marked “A”, “B”, and “C”.
LAMP OPTIMIZATION
Unlike traditional discharge lamps the Phillips Platinum 15R PRO Lamp does NOT
require optimization. The lamp orientation and optimization procedure has been
preset during the manufacturing process of the lamp.
Please remember the Phillips Platinum 15R PRO Lamp is NOT a hot-restrike lamp
therefore, you must wait approximately 15 minutes before you can attempt to
restrike the lamp once it has been turned off.