Elation Power Wash 250 handleiding

40 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 10 van 40
Power Wash 250™
©Elation Professionals® Los Angeles, Ca. 90058 - www.ElationLighting.com - Page 10
12. DMX Input Jack – This jack is used to receive an incoming DMX signal or
Master/Slave signal.
13. DM X Output Jack – This jack is used to transmit the incoming DMX signal
to another DMX fixture, or transmit a Master/Slave signal to the next Power
Wash 250™ in the chain. For best results in DMX or Master/Slave mode
terminate this jack if it is the last fixture in the chain. See “Terminator” on
page 14.
14. Power Switch – This switch is used to control main power to the fixture.
15. Fuse Holder – This housing stores a 6.3 amp (3.15 amp 220v) GMA
protective fuse. Never defeat the fuse, the fuse is designed to protect the
electronics in the event of sever power fluctuations. Always be sure to replace
the fuse with an exact match as to the one being replaced, unless otherwise
told to do so by an authorized Elation® service technician.
16. Cooling Fan - This fixture is equipped with a high velocity variable fan to aid in
the cooling process. This fan is designed to vary its’ velocity at different
operating temperatures, to provide better cooling when the fixture reached
higher operating temperatures associated with long usage. Be sure to never
obstruct the cooling fan during normal usage. Also, be sure to keep this vent
clean at all times. A blocked or malfunctioning cooling system may shorten
lamp life and fixture reliability.

Bekijk gratis de handleiding van Elation Power Wash 250, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkElation
ModelPower Wash 250
CategorieVerlichting
TaalNederlands
Grootte4107 MB