Elation Platinum Seven handleiding

32 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 29 van 32
29
ELATION PLATINUM SEVEN
E R R O R C O D E S
Error Codes subject to change without notice.
ERROR CODE
DESCRIPTION
PAN
The PAN movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit malfunctions
(sensor failed or magnet is missing) or there is a motor failure (defective motor or a
defective motor IC drive on the main PCB). This error may also be displayed if the
head/yoke was blocked during a reset function.
TILT
The TILT movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit malfunctions
(sensor failed or magnet is missing) or there is a motor failure (defective motor or
defective motor IC drive on main PCB). This error may also be displayed if the head was
blocked during a reset function.
ZOOM
The Zoom movement is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or defective motor IC drive on main PCB).
Fan Error
Head fan error, displayed as “Fan RPM <1000”