Elation Platinum Beam 5R handleiding
Handleiding
Je bekijkt pagina 8 van 27

6
Before replacing the lamp let the lamp cool down, because during operation, the lamp can
reach very high temperature.
During the installation of halogen lamps do not touch the glass bulbs bare handed. Always use a
cloth to handle the lamps during insertion and removal.
Do not install lamps with a higher wattage. They generate higher temperatures than which the
device was designed for.
For the installation, you need one: PLATINUM 5R
Procedures:
1) Unscrew the 2 screws (A, B) on the bottom of the housing, holding the plate where the lamp
is underneath. Carefully remove the metal plate.
2) Insert the lamp counter-clockwise 35 degree into the lampholder, then turn clockwise 35
degree to put it into the right position. Attention: please wrap the lamp with the soft cloth that
comes with the packing, avoid naked hand contact to the lamp directly.
3) Put the lampholder back position after install the lamp, tighten the screw and complete the
installation.
Please remember the lamp is not a hot-restrike type, you must wait for approximately 10
minutes after having turned off the lamp before you can turn it back on again.
b) Mounting the device
The applicable temperature for the lighting is between -25°C to 45°C. Do not use the lighting
under or above the temperature.
The installation of the effect has to be built and constructed in a way that it can hold 10 times the
XM485-V1.0-NR